You're reading an old version of this documentation. For the latest released version, please have a look at v5.0.1.
Extended Mobile Phase Modulator Langmuir¶
Group /input/model/unit_XXX/adsorption – ADSORPTION_MODEL = EXTENDED_MOBILE_PHASE_MODULATOR
IS_KINETIC
Selects kinetic or quasi-stationary adsorption mode: 1 = kinetic, 0 = quasi-stationary. If a single value is given, the mode is set for all bound states. Otherwise, the adsorption mode is set for each bound state separately.
Type: int |
Range: {0,1} |
Length: 1/NTOTALBND |
EMPM_COMP_MODE
Determines the mode of each component (\(0\) denotes the modifier component, \(1\) is linear binding, \(2\) is modified Langmuir binding). At most one modifier component is allowed, that is, a modifier is not required.
Note that this field has the same name for the externally dependent variant of the model.
Type: int |
Range: \(\{0,1,2\}\) |
Length: NCOMP |
EMPM_KA
Adsorption rate constants
Unit: \(m_{MP}^3~mol^{-1}~s^{-1}\)
Type: double |
Range: \(\ge 0\) |
Length: NCOMP |
EMPM_KD
Desorption rate constants
Unit: \(m_{MP}^{3\beta}~mol^{-\beta}~s^{-1}\)
Type: double |
Range: \(\ge 0\) |
Length: NCOMP |
EMPM_QMAX
Maximum adsorption capacities
Unit: \(mol~m_{SP}^{-3}\)
Type: double |
Range: \(\ge 0\) |
Length: NCOMP |
EMPM_BETA
Parameters describing the ion-exchange characteristics (IEX)
Unit: \(mol~m_{SP}^{-3}\)
Type: double |
Range: \(\ge 0\) |
Length: NCOMP |
EMPM_GAMMA
Parameters describing the hydrophobicity (HIC)
Unit: \(m_{MP}^{3} mol^{-1}\)
Type: double |
Range: \(\ge 0\) |
Length: NCOMP |