You're reading the documentation for a development version. For the latest released version, please have a look at v5.0.3.
Freundlich LDF¶
Group /input/model/unit_XXX/adsorption – ADSORPTION_MODEL = FREUNDLICH_LDF
For information on model equations, refer to Freundlich LDF.
IS_KINETIC
Selects kinetic or quasi-stationary adsorption mode: 1 = kinetic, 0 = quasi-stationary. If a single value is given, the mode is set for all bound states. Otherwise, the adsorption mode is set for each bound state separately.
Type: int |
Range: {0,1} |
Length: 1/NTOTALBND |
FLDF_KKIN
Driving force coefficient for each component
Unit: \(s^{-1}\)
Type: double |
Range: \(\ge 0\) |
Length: 1/NTOTALBND |
FLDF_KF
Freundlich coefficient for each component
Unit: \(m_{MP}^{3/n}~m_{SP}^{-3}~mol^{1-1/n}\)
Type: double |
Range: \(\ge 0\) |
Length: 1/NTOTALBND |
FLDF_N
Freundlich exponent for each component
Unit: [-]
Type: double |
Range: \(> 0\) |
Length: 1/NTOTALBND |